FIELD TRIP GUIDE FOR THE INTERNATIONAL FIELD CONFERENCE AND WORKSHOP ON TEPHROCHRONOLOGY AND VOLCANISM
citation imageFroese, D.G, Westgate, J.A., and Alloway, B.V., (eds.), 2005, Field trip guide for the International Field Conference and Workshop on Tephrochronology and Volcanism: Institute of Geological and Nuclear Sciences Science Report 2005/26, Dawson City, Yukon Territory, Canada, July 31-August 8, 2005, 132 p.

DATA TABLES *Not all tables in a publication may be listed. Not all tables from a publication have data entered in the database.
3701: Major element composition of Northern and Eastern Lobes of the White River Ash
View table data :: Download table data (.csv)
* Note. Major element-element analyses done on a JEOL superprobe operating at a 15keV accelerating voltage, 5 mm [sic? Should this be microns?] beam diameter, and 6nA beam current at the University of Alberta. Standardization to obsidian standard UA5831, recast to 100% on a water-free basis; (#)= standard standard deviation; n =number of analysis; FeOt =total iron oxide as FeO; H2Od =water by difference. *
3711: Average glass major-and trace element compisitions [sic] of Sheep Creek-like tephra beds.
View table data :: Download table data (.csv)
* Notes: All major-element analyses done on a Cameca SX-50 wavelength dispersive electron microprobe. Trace-element analyses for Ash Bend, SCT-K and SCT-F performed by solution nebulisation inductively coupled plasma mass spectrometry (ICP-MS) using a VG Plasma-Quad PQ II. Trace-element analyses for SCT-C performed by laser ablation ICP-MS using a Mercantec LUV266 laser ablation system and a VG Plasma-Quad PQ II. Major-element analyses recast to 100% on a water-free basis; (#) = standard deviation; n = number of analyses; FeOt = total iron oxide as FeO; H2Od =water by difference; n.d. =not determined. *
3721: Major and trace element composition of glass shards from tephra beds within Midnight Dome Loess.
View table data :: Download table data (.csv)
* Notes: All major-element analyses done on a Cameca SX-50 wavelength dispersive electron microprobe. Trace-element analyses performed by solution nebulisation inductively coupled plasma mass spectrometry (ICP-MS) using a VG Plasma-Quad PQ Il. Major-element analyses recast to 100% on a water-free basis;(#)= standard deviation; n =number of analyses; FeOt =total iron oxide as FeO; H2Od = water by difference. Note that this composition of the Midnight Dome tephra was previously reported by Westgate et al. (2001) and is therefore not included in this table. *
3731: Average glass major- and trace-element compositions of VT tephra bed at Fairbanks AK and Jackson Hill, YK.
View table data :: Download table data (.csv)
* Notes: All major-element analyses done on a Cameca SX-50 wavelength dispersive electron microprobe. Trace-element analyses for VT at Paradise Hill performed by solution nebulisation inductively coupled plasma mass spectrometry (ICP-MS) using a VG Plasma-Quad PQ II. Trace element analyses for VT at Fairbanks performed by the instrumental neutron activation technique (INAA). Major-element analyses recast to 100% on a water-free basis; (#) = standard deviation; n = number of analyses; FeOt = total iron oxide as FeO; H2Od = water by difference; n.d. = not determined. Note that the VT tephra composition in Fairbanks is reported in this table; however, these analyses of this tephra were previosly reported in Preece et al. (1999) and therefore the are not re-entered into the database. *
3741: Average glass major- and trace-element compositions of tephra beds in the Paradise Hill Area.
View table data :: Download table data (.csv)
* Notes: All major-element analyses done on a Cameca SX-50 wavelength dispersive electron microprobe. Trace-element analyses for Paradise Hill and Dago Hill performed by solution nebulisation inductively coupled plasma mass spectrometry (ICP-MS) using a VG Plasma-Quad PQ II. Trace-element analyses for Little Blanche Creek performed by laser ablation ICP-MS using a Mercantec LUV266 laser ablation system and a VG Plasma-Quad PQ II. Major-element analyses recast to 100% on a water-free basis; (#) = standard deviation; n = number of analyses; FeO = total iron oxide as FeO; H2Od =water by difference; n.d. =not determined. Note that the composition of the Little Blanche Creek tephra at Quartz Creek is reported in this table; however, the same analyses of this tephra were previously by Preece et al. (2000) and there are not re-entered into the databse. *
3751: Average glass major- and trace-element compositions of Quartz Creek tephra bed.
View table data :: Download table data (.csv)
* Notes: All major-element analyses done on a Cameca SX-50 wavelength dispersive electron microprobe. Trace-element analyses performed by solution nebulisation inductively coupled plasma mass spectrometry (ICP-MS) using a VG Plasma-Quad PQ II. Major-element analyses recast to 100% on a water-free basis; (#)=standard deviation; n =number of analyses; FeOt =total iron oxide as FeO; H2Od = water by difference. *
3761: Average glass major- and trace-element compositions of Lucky Lady tephra.
View table data :: Download table data (.csv)
* Notes: All major-element analyses done on a Cameca SX-50 wavelength dispersive electron microprobe. Trace-element analyses performed by solution nebulisation inductively coupled plasma mass spectrometry (ICP-MS) using a VG Plasma-Quad PQ II. Major-element analyses recast to 100% on a water-free basis; (#) =standard deviation; n = number of analyses; FeOt = total iron oxide as FeO; H2Od = water by difference. *
3771: Glass composition and fission track age of Gold Run tephra.
View table data :: Download table data (.csv)
* Notes: All major-element analyses done on a Cameca SX-50 wavelength dispersive electron microprobe. Trace-element analyses performed by solution nebulisation inductively coupled plasma mass spectrometry (ICP-MS) using a VG Plasma-Quad PQ II. Major-element analyses recast to 100% on a water-free basis; (#)=standard deviation; n =number of analyses; FeOt =total iron oxide as FeO; H2Od = water by difference. *

SAMPLES
Contact AVO Privacy Accessibility Information Quality FOIA
URL: www.avo.alaska.edu/downloads/reference.php
Page modified: June 22, 2022 08:39